Schneider Electric AP8866 PDU 2G Metered ZeroU 17.2kW 208V (6) C13 and (12) C19
Couldn't load pickup availability
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
- Power Rating: 17.30 kVA
- Output Receptacles: 6 x IEC 60320 C13
- Output Receptacles: 12 x IEC 60320 C19
- Input Voltage: 208 V AC Three-phase
- Output Voltage: 208 V AC
- Current: 48 A Derated Input Current
- Current: 48 A Line Current Per Phase
- Current: 60 A Input Current Per Phase
- Current: 48 A Total Current Draw Per Phase
- Color: Black
- Form Factor: Zero U Rack-mountable
- Power Cord/Cable: 1 x 6 ft
- Height: 72.0 and quot
- Width: 2.2 and quot
- Depth: 2.0 and quot
- Weight (Approximate): 20.94 lb
Materials
Materials
Shipping & Returns
Shipping & Returns
Dimensions
Dimensions
Care Instructions
Care Instructions

Image with text
Pair text with an image to focus on your chosen product, collection, or blog post. Add details on availability, style, or even provide a review.
-
Free Shipping
Pair text with an image to focus on your chosen product, collection, or blog post. Add details on availability, style, or even provide a review.
-
Hassle-Free Exchanges
Pair text with an image to focus on your chosen product, collection, or blog post. Add details on availability, style, or even provide a review.
Schneider Electric AP8866 PDU 2G Metered ZeroU 17.2kW 208V (6) C13 and (12) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
- Power Rating: 17.30 kVA
- Output Receptacles: 6 x IEC 60320 C13
- Output Receptacles: 12 x IEC 60320 C19
- Input Voltage: 208 V AC Three-phase
- Output Voltage: 208 V AC
- Current: 48 A Derated Input Current
- Current: 48 A Line Current Per Phase
- Current: 60 A Input Current Per Phase
- Current: 48 A Total Current Draw Per Phase
- Color: Black
- Form Factor: Zero U Rack-mountable
- Power Cord/Cable: 1 x 6 ft
- Height: 72.0 and quot
- Width: 2.2 and quot
- Depth: 2.0 and quot
- Weight (Approximate): 20.94 lb